An intersection should be modeled as its own lighting zone using the actual approaches, turning areas, medians, islands, crossings where included, mast-arm conflicts, signs, and pole constraints. Fixture output, distribution, orientation, and pole locations should be checked across the whole junction and its transitions to adjacent road segments. This guide is for roadway designers, traffic consultants, contractors, developers, and lighting suppliers who need to turn an intersection plan into a coordinated photometric model and a clear luminaire schedule. It focuses on the inputs, checks, and handoff records that make the final design reviewable.
Map the Complete Junction Geometry
Start by drawing the complete junction, not just the paved center. The design boundary should show where each approach enters the intersection, where turning movements occupy space, and where the junction transitions back to ordinary roadway lighting.
Record the following inputs before choosing a luminaire or pole location:
- Lane lines, lane widths, turn pockets, merge areas, shoulders, bike lanes, sidewalks, and marked crossings included in the project.
- Medians, traffic islands, channelization, splitter islands, curb returns, gore areas, tapers, and other changes in pavement geometry.
- Curves, grades, superelevation where relevant, and any vertical or horizontal feature that changes sight lines or mounting feasibility.
- Signals, signs, sign supports, overhead lines, drainage structures, utilities, trees, barriers, and planned roadside equipment.
- Existing poles, foundations, service points, underground routes, and access requirements for installation and maintenance.
Define two boundaries: the central conflict area and the transition zones on each approach. The central area contains the crossing, turning, merging, and decision locations that need to be evaluated together. The transition zones extend far enough along each approach to test whether a bright center is followed by an abrupt weak area. The exact length and performance criteria should follow the project authority, adopted design practice, and the roadway classification; they should not be invented from a generic rule of thumb.
Intersection Input Checklist
| Input group | What to record | Why it changes the design |
| Geometry | Approaches, lanes, turn pockets, medians, islands, curves, grades | Determines calculation grids, coverage, and pole feasibility |
| Traffic equipment | Signals, mast arms, signs, detection equipment, crossings | Creates clearance, sight-envelope, and aiming constraints |
| Roadside constraints | Utilities, overhead lines, drainage, barriers, trees, property limits | May move poles or restrict outreach and maintenance access |
| Existing system | Pole IDs, foundations, voltage, controls, fixture locations | Determines reuse, replacement, and interface options |
| Design boundary | Central area plus approach transition/tie-in segments | Prevents a well-lit center from masking weak approaches |
For a complete product-selection workflow, use the LED street-light buying guide, but keep the intersection geometry as the controlling input rather than starting from a catalog wattage.
Coordinate Lighting Poles with Intersection Equipment
Pole placement is a joint civil, traffic, structural, utility, and photometric decision. A location that looks efficient in a lighting plan may obstruct a signal sight envelope, conflict with a mast arm, reduce maintenance access, or create an unacceptable foundation condition.
Shared supports can reduce visual clutter and civil work, but they should be used only when the responsible structural and traffic teams approve the arrangement. A shared signal/light support is not automatically equivalent to a dedicated lighting pole. Confirm loading, foundation design, vibration, access, electrical separation, ownership, and future maintenance responsibility before treating it as an option.
For every proposed luminaire, record the exact coordinate, mounting elevation, outreach length, azimuth, tilt, and intended orientation. Use one coordinate system and one pole-ID convention across the civil plan, signal plan, photometric model, electrical drawings, and schedule. Small differences between a drawing coordinate and the modeled coordinate can change overlap, glare, and dark pockets near the conflict area.
Coordination Matrix
| Coordination item | Design question | Required project record |
| Signal poles and mast arms | Does the luminaire clear signal hardware and preserve the required sight envelope? | Pole ID, clearance note, responsible approval |
| Overhead lines and utilities | Is the mounting point and outreach compatible with electrical and underground constraints? | Utility plan reference and clearance confirmation |
| Signs and sign supports | Will the luminaire, arm, or maintenance vehicle interfere with sign visibility or access? | Sign ID, offset, maintenance note |
| Structural support | Can the pole, arm, foundation, and shared equipment carry the proposed loads? | Structural design or approval reference |
| Photometric position | Does the actual coordinate match the calculation model? | X/Y/elevation, azimuth, tilt, model revision |
The FY LIGHTING LED street-light product page can help explain layout geometry, but an intersection should not be reduced to a repeating mid-block spacing pattern. Each pole has a role in the junction model.
Select Optics for Approaches and Central Conflict Areas
Do not assume that every luminaire in an intersection should use the same optic. The correct distribution depends on the approach direction, mounting side, pole position, junction width, median geometry, and the locations of the surfaces that must be evaluated.
Review each approach separately. A distribution that throws light across one leg may leave the far side of another leg weak. Asymmetric throw can help place light where the roadway extends away from a pole, while a broader distribution may be useful for an open central area. These are photometric choices, not labels that can be selected without a layout.
For each pole, test the following:
- The intended approach or conflict-area role.
- The optic or distribution family and the mounting height used in the model.
- Rotation and orientation relative to the roadway centerline, curb, crossing, or median.
- Overlap with neighboring luminaires and the far-side coverage required by the geometry.
- Localized maximums, minimums, dark pockets, and unwanted spill beyond the design boundary.
Use contours and calculation grids to find problems that an average value can hide. A central average may look acceptable while a turning path, island, crossing, or far-side lane remains below the project criterion. Conversely, adding output to fix one pocket can create a localized peak or excessive spill. The useful question is not “Which optic is strongest?” but “Which distribution places the required light on the relevant surfaces under the approved criteria?”
Approach-by-Approach Optic Schedule
| Approach or zone | Pole IDs | Mounting side/height | Optic and rotation | Primary check |
| North approach | Project-specific | Project-specific | Project-specific | Tie-in uniformity and far-side coverage |
| East approach | Project-specific | Project-specific | Project-specific | Turn pocket and cross-junction overlap |
| South approach | Project-specific | Project-specific | Project-specific | Median/island coverage and dark pockets |
| West approach | Project-specific | Project-specific | Project-specific | Curve, grade, and transition performance |
| Central conflict area | Project-specific | Project-specific | Project-specific | Local minimums, peaks, and overlap |
For more detail on output, illuminance, uniformity, and optics, link to the FY LIGHTING LED street-light product page. It should support the model—not replace the actual IES/LDT file and project calculation.
Model the Junction and Adjacent Transitions
Build one coordinated model that includes the central intersection, each approach, and the tie-in segments. Use consistent assumptions for pole coordinates, mounting heights, roadway surfaces, calculation grids, operating states, and luminaire photometry. If one approach is modeled with different assumptions, label the difference and explain why.
The model should allow reviewers to inspect at least:
- The central conflict area and each approach separately.
- Turning areas, medians, islands, crossings, and other included surfaces.
- Minimum values, average values, maximum values, and the applicable uniformity metrics.
- Orientation and output under each operating state, including any approved dimming or control state.
- The transition from the junction to adjacent roadway lighting, including tie-in fixtures or existing assets.
Do not use a generic illuminance target in place of the project’s adopted criteria. The Federal Highway Administration describes its Lighting Handbook as a resource for evaluating roadway-lighting needs and applications rather than a detailed design guide. AASHTO roadway-lighting guidance and ANSI/IES recommended practices may inform the design, but the governing agency, contract documents, and current local requirements determine the criteria for a specific project. The FHWA roadway lighting resources provide a useful starting point for official guidance and research references.
Result-Review Map
| Model area | Review result | Decision if weak or excessive |
| Central conflict area | Minimums, peaks, overlap, crossing/turning coverage | Adjust optic, orientation, position, or output and rerun |
| Each approach | Grid results and direction-specific coverage | Recheck approach optic and pole role |
| Medians and islands | Localized values and visibility of physical boundaries | Modify aiming or add a suitable location only if justified |
| Transition/tie-in segments | Continuity with adjacent roadway lighting | Extend model, coordinate tie-in, or revise operating state |
| Operating states | Results for each approved control condition | Confirm controls do not create an unreviewed weak state |
A calculation is not complete when the software produces a pass-colored summary. Save the model revision, photometric file version, assumptions, calculation grids, contour plots, and review comments. If a fixture is changed, rerun the affected areas and confirm that the schedule, drawings, and model still agree.
Commission Orientation and Controls at the Junction
Commissioning should verify the installed configuration, not merely confirm that the luminaires turn on. At an intersection, a small rotation, tilt, optic substitution, or output setting can move light away from a critical approach and create a result that no longer matches the approved model.
Use a pole-by-pole commissioning sheet with these fields:
- Project, intersection, date, weather, measurement method, and responsible personnel.
- Pole ID, fixture model, serial or asset reference, optic, output setting, voltage, control group, and quantity.
- Mounting height, arm length, azimuth/rotation, tilt, and any field adjustment from the approved drawing.
- Photometric file or configuration revision used for acceptance comparison.
- Nighttime observation notes, field measurements under the approved method, photographs where permitted, and unresolved items.
- Final disposition: accepted, corrected and retested, or held for design review.
The FY LIGHTING LED street-light product page can support the mechanical, electrical, and control-interface handoff. It does not replace the project’s approved electrical design, inspection method, or authority requirements.
If a field condition requires relocation or a different optic, document it as a controlled change. Do not silently move the fixture and leave the old coordinate in the schedule. The designer should determine whether the change requires a new photometric run, structural review, utility clearance review, or revised approval.
Issue an Intersection Luminaire Schedule
The luminaire schedule is the procurement and installation handoff. It should allow a supplier, contractor, inspector, and designer to identify what belongs at each pole without interpreting a general product description.
At minimum, list the following for every asset:
| Schedule field | Required entry |
| Asset identification | Intersection, approach/zone, pole ID, luminaire ID, quantity |
| Product | Manufacturer, model/series, output or lumen package, optic/distribution |
| Mounting | Mount type, arm/outreach, mounting height, orientation, rotation, tilt |
| Electrical | Input voltage, circuit or control group, dimming/control interface |
| Documentation | Photometric file revision, drawing revision, approved configuration |
| Procurement status | Approved source, substitution status, notes and required approvals |
Do not leave “equivalent” undefined. Any substitution should identify the proposed model, output, optic, mounting interface, control behavior, photometric file, and effect on the approved calculation. A different wattage or lumen package is not automatically equivalent if its distribution, dimensions, driver behavior, or control interface changes.
After the reader has established the geometry, coordination constraints, optics, model checks, and commissioning records, the supplier handoff can be specific. Send FY LIGHTING the intersection plan, approach geometry, pole and signal constraints, mounting dimensions, target criteria, voltage, controls, and pole-by-pole schedule. FY LIGHTING can identify candidate SLE roadway and area-light optics and output options for the project designer’s junction calculation. The SLE series is documented with 100/150/200/300 W options, up to 170 lm/W, IP65, Type III/IV/V distributions, and several mounting options; final suitability, configuration, and certification must be confirmed for the exact project model and market.
Recommended Handoff Process
- Freeze the latest civil, signal, utility, and lighting base plans.
- Assign pole and asset IDs and verify all modeled coordinates.
- Confirm the target criteria and transition boundary with the responsible authority.
- Select candidate optics and output packages for each approach and zone.
- Run the full junction-and-transition model and record the assumptions.
- Review contours, grids, minimums, uniformity, peaks, orientation, and control states.
- Issue the pole-by-pole schedule with matching drawings and photometric files.
- Require documented approval for substitutions, relocations, optic changes, or control changes.
- Commission the installed configuration and close every deviation through retesting or design approval.
Conclusion and Project CTA
Intersection street lighting design is a coordinated zone-design task, not an extension of ordinary pole spacing. Begin with the complete geometry, coordinate poles with signals and utilities, select optics by approach role, model the junction and transitions together, and preserve the installed configuration in a pole-by-pole schedule. Send the intersection plan, approach geometry, pole and signal constraints, mounting dimensions, target criteria, voltage, controls, and luminaire schedule to the supplier team for a configuration review based on the exact application.
Frequently Asked Questions
Can Intersection Lights Use the Same Optic as the Road?
Sometimes, but not automatically. Each approach and pole position must be checked because an intersection changes the direction of throw, overlap, turning-area coverage, and far-side requirements. Use the roadway optic only when its photometric distribution and orientation satisfy the intersection and transition calculations.
Where Should Intersection Poles Be Placed?
Place them through coordinated civil, traffic, utility, structural, and photometric design. A suitable location must clear signals and signs, preserve sight envelopes, support the required mounting arrangement, remain accessible for maintenance, and produce acceptable results in the full junction model. There is no universal offset that replaces this review.
Should the Approaches Be Included in the Model?
Yes, when they are part of the lighting decision or connect to the junction. The model should include enough transition or tie-in length to review continuity with adjacent roadway lighting under the project’s adopted criteria. A bright central area does not prove that the approach transitions are adequate.
How Is Fixture Orientation Controlled?
Control it with consistent pole IDs, coordinates, drawings, labels, azimuth or rotation values, tilt values, and commissioning records. The installed optic and aiming should be checked against the approved model. Any field relocation or re-aiming that changes the modeled condition should be documented and reviewed.
Sources
- FHWA Roadway Lighting Resources— official roadway-lighting resources, handbook context, intersection research references, and design materials.
- FHWA Lighting Handbook— official description of the handbook’s application and guidance scope.
- AASHTO Roadway Lighting Design Guide, 7th Edition listing— roadway-lighting design guide reference for agency practice.
- Main Roads WA Lighting Design Guideline— example of agency requirements covering intersection lighting, components, software, documentation, and current referenced standards.